import {protectionLabels} from './protection';
import {useEffect,useRef,useState} from 'react';
import {Button,ConfirmationModal,Description,SettingsCard,Switch} from '@nodedc/ui-react';
import {perform,type Sensor,type SensorTransport} from '../../../../packages/sensor-ui/src/contracts';
import {batteryState,number,type BmsSettingsSnapshot,type BmsSwitch} from './model';
const switchNames:Record<BmsSwitch,string>={charging:'Заряд',discharging:'Разряд',balancing:'Балансировка'};
const fields:readonly [string,string,string][]=[
['nominal_capacity_ah','Настроенная ёмкость','А·ч'],['cell_count','Количество ячеек',''],
['cell_uvp_v','Защита от низкого напряжения ячейки','В'],['cell_uvpr_v','Восстановление после низкого напряжения','В'],
['cell_ovp_v','Защита от высокого напряжения ячейки','В'],['cell_ovpr_v','Восстановление после высокого напряжения','В'],
['soc0_voltage_v','Порог 0%','В'],['soc100_voltage_v','Порог 100%','В'],
['requested_charge_voltage_v','Запрошенное напряжение заряда на ячейку','В'],['requested_float_voltage_v','Запрошенное поддерживающее напряжение','В'],
['poweroff_voltage_v','Порог отключения BMS','В'],['sleep_voltage_v','Порог сна','В'],
['max_charge_current_a','Предельный ток заряда','А'],['charge_ocp_delay_s','Задержка защиты заряда','с'],['charge_ocp_recovery_s','Восстановление защиты заряда','с'],
['max_discharge_current_a','Предельный ток разряда','А'],['discharge_ocp_delay_s','Задержка защиты разряда','с'],['discharge_ocp_recovery_s','Восстановление защиты разряда','с'],
['short_circuit_delay_us','Задержка защиты КЗ','мкс'],['short_circuit_recovery_s','Восстановление после КЗ','с'],
['balance_start_voltage_v','Напряжение начала балансировки','В'],['balance_trigger_v','Разница для начала балансировки','В'],['max_balance_current_a','Предельный ток балансировки','А'],
['charge_overtemp_c','Защита заряда от перегрева','°C'],['charge_overtemp_recovery_c','Восстановление заряда после перегрева','°C'],
['discharge_overtemp_c','Защита разряда от перегрева','°C'],['discharge_overtemp_recovery_c','Восстановление разряда после перегрева','°C'],
['charge_undertemp_c','Защита заряда от переохлаждения','°C'],['charge_undertemp_recovery_c','Восстановление заряда после холода','°C'],
['mos_overtemp_c','Защита MOS от перегрева','°C'],['mos_overtemp_recovery_c','Восстановление MOS после перегрева','°C'],
];
export function BmsSettings({device,transport,enabled,open,section,refresh}:{device:Sensor;transport:SensorTransport;enabled:boolean;open:boolean;section:'diagnostics'|'protection'|'control';refresh:()=>Promise<void>}){
const [now,setNow]=useState(Date.now()),[busy,setBusy]=useState(false),[error,setError]=useState(''),[message,setMessage]=useState('');
const [read,setRead]=useState<{settings:BmsSettingsSnapshot;link_generation:number;at:number}|null>(null);
const [proposal,setProposal]=useState<{name:BmsSwitch;enabled:boolean;settings:BmsSettingsSnapshot;link_generation:number}|null>(null);
const latest=useRef(device);latest.current=device;
useEffect(()=>{const timer=setInterval(()=>setNow(Date.now()),1000);return()=>clearInterval(timer);},[]);
const state=batteryState(device,enabled,now),sample=state.sample;
const settings=read&&!(Date.parse(state.settings_at??'')>read.at)?read.settings:state.settings;
const readSettings=async()=>{setBusy(true);setError('');try{const value=await perform<{settings:BmsSettingsSnapshot;link_generation:number}>(transport,latest.current,'bms.read',{},20000);setRead({...value,at:Date.now()});await refresh();return value;}catch(reason){setError(reason instanceof Error?reason.message:'Не удалось прочитать BMS.');return null;}finally{setBusy(false);}};
useEffect(()=>{if(open&&enabled)void readSettings();},[open,device.id,enabled]);
const propose=async(name:BmsSwitch,value:boolean)=>{const result=await readSettings();if(result)setProposal({name,enabled:value,...result});};
const apply=async()=>{if(!proposal)return;setBusy(true);setError('');try{const result=await perform<{settings:BmsSettingsSnapshot}>(transport,device,'bms.control.set',{switch:proposal.name,enabled:proposal.enabled,fingerprint:proposal.settings.fingerprint,link_generation:proposal.link_generation},20000);setRead({settings:result.settings,link_generation:proposal.link_generation,at:Date.now()});setProposal(null);setMessage('BMS подтвердила запрошенное состояние.');await refresh();}catch(reason){setError(reason instanceof Error?reason.message:'Результат не подтверждён.');setProposal(null);}finally{setBusy(false);}};
const facts=(rows:readonly (readonly [string,string])[])=><dl className="bms-facts">{rows.map(([label,value])=><div key={label}><dt>{label}</dt><dd>{value}</dd></div>)}</dl>;
return <div className="bms-content">
<Button disabled={!state.fresh||busy} loading={busy} onClick={()=>void readSettings()}>Обновить данные BMS</Button>
{!state.fresh&&<Description>Показаны последние сведения. Управление доступно при свежем соединении.</Description>}
{error&&<Description role="alert">{error}</Description>}{message&&<Description role="status">{message}</Description>}
{section==='diagnostics'&&<>
<SettingsCard title="Аккумулятор">{facts([
['Модель BMS',state.identity?.model??'—'],['Аппаратная версия',state.identity?.hardware??'—'],['Прошивка',state.identity?.firmware??'—'],['Серийный номер BMS',state.identity?.serial_number??'—'],['Дата производства · BMS',state.identity?.manufactured_raw??'—'],
['Расчётная ёмкость BMS',`${number(sample?.effective_capacity_ah,2)} А·ч`],['Состояние здоровья · оценка BMS',`${number(sample?.reported_health_percent,0)} %`],
['Среднее напряжение ячеек',`${number(sample?.cell_average_v,3)} В`],['Минимальная ячейка',sample?.cell_min_index?`${sample.cell_min_index} · ${number(sample.cell_min_v,3)} В`:'—'],['Максимальная ячейка',sample?.cell_max_index?`${sample.cell_max_index} · ${number(sample.cell_max_v,3)} В`:'—'],
])}<Description>Оценка BMS не заменяет измерение фактической ёмкости аккумулятора.</Description></SettingsCard>
<SettingsCard title="Измерительные провода">{facts((sample?.wire_resistances_ohm??[]).map((v,i)=>[`Ячейка ${String(i+1).padStart(2,'0')}`,`${number(v*1000,0)} мОм${sample?.wire_warning_cells?.includes(i+1)?' · предупреждение':''}`]))}<Description>Сопротивление измерительной цепи, не внутреннее сопротивление ячейки.</Description></SettingsCard>
<SettingsCard title="Защита">{facts([['Флаги BMS',sample?.protection_mask!=null?'0x'+sample.protection_mask.toString(16).padStart(8,'0'):'—'],['Состояния',protectionLabels(sample?.protection_mask).join('; ')||'Нет активных флагов'],['Предупреждения проводов',sample?.wire_warning_cells?.join(', ')||(sample?'Нет':'Нет данных')]])}</SettingsCard>
</>}
{section==='protection'&&<SettingsCard title="Параметры защиты и балансировки" description="Текущие значения из BMS. Только чтение: пороги, калибровки и конфигурация здесь не изменяются.">{settings?facts(fields.map(([key,label,unit])=>[label,`${number(settings.values[key],unit==='В'?3:1)} ${unit}`])):<Description>Настройки ещё не прочитаны.</Description>}</SettingsCard>}
{section==='control'&&<SettingsCard title="Заряд, разряд и балансировка" description="Каждое изменение требует подтверждения и проверяется повторным чтением BMS.">
{(Object.keys(switchNames) as BmsSwitch[]).map(name=><Switch key={name} label={switchNames[name]} checked={settings?.switches[name]===true} disabled={!state.fresh||!settings||!state.control_available||busy} onChange={value=>void propose(name,value)}/>)}
{state.control_locked&&<Description role="alert">Результат записи не подтверждён. Управление заблокировано; автоматического повтора нет.</Description>}
<Description>Разряд питает нагрузку. Его отключение может обесточить борт и прекратить удалённое управление. Разрешение заряда или разряда не отменяет защиты BMS.</Description>
</SettingsCard>}
<ConfirmationModal open={!!proposal} title={`${proposal?.enabled?'Включить':'Выключить'} ${proposal?switchNames[proposal.name].toLocaleLowerCase('ru-RU'):''}?`} danger confirmLabel="Подтвердить" onClose={()=>{if(!busy)setProposal(null);}} onConfirm={apply}
description={proposal?.name==='discharging'&&!proposal.enabled?'Отключение разряда может обесточить борт. Для восстановления связи может потребоваться физический доступ к аккумулятору.':'Изменится только выбранный рабочий переключатель. Пороги защиты и калибровки останутся прежними.'}/>
</div>;
}