4.2 KiB
ADR 0028 — E35 deterministic degradation and recovery
Date: 2026-07-27
Status: accepted and executed
Context
E32 fixes camera-owned semantic identity and exclusive map-frame point
ownership over all 4,489 immutable RAVNOVES00 frames. E33 proves bounded
recorded-source-paced delivery. E34 adds a separate hit-only temporal layer
with explicit current/occupied, held/unknown and expired/unknown state.
Those nominal results do not yet prove that the composed pipeline fails safely when camera, LiDAR, pose or delivery timing degrades. A fault must not retain a semantic or metric claim that its required evidence no longer supports. It must also not turn missing data into free space or reintroduce a stale result after the fault window.
Predeclared decision
- E35 derives six immutable variants from the exact accepted E32/E33/E34 chain. It never mutates the source or any accepted upstream result.
- Each variant replays all 4,489 source frames. One bounded, non-overlapping interval carries exactly one deterministic transformation: camera loss, LiDAR loss, pose staleness, delayed frames, bounded frame drops or camera↔LiDAR timing offset.
- Camera loss removes camera observations. Current metric point ownership is
retained only as unknown-class
geometry-only; E35 cannot preserve or invent semantic class. - LiDAR loss retains camera identity as
camera-onlybut removes current metric rows. Prior occupied evidence may age through the E34 held/expired contract, but no new occupied or free cells may be created. - Pose age of
0.5 sexceeds the accepted0.1 sbinding gate. Map-frame points are therefore withheld and camera claims remain non-metric. - A deterministic
1.0 sdelivery delay exceeds the0.75 soccupied TTL. Delayed results are explicitly discarded and may not re-enter after their logical deadline. - The bounded-drop variant drops every third frame in its 60-frame interval. Every drop is journalled; intervening frames remain ordered and the layer exposes held/expired uncertainty instead of silent continuity.
- A
250 mscamera↔LiDAR offset exceeds the admitted binding. Camera observations and point-backed geometry are split into separatecamera-onlyandgeometry-onlyevidence. The mismatched pair cannot publishagree. - Every variant records one terminal outcome per source frame, every injected transformation, layer-state transitions, current/held/expired counts, excluded semantic/metric claims, recovery time and artifact digests.
- Acceptance requires six complete 4,489-frame variants, exact unchanged
upstream artifacts, zero hidden success, zero false-free rows, zero
semantic claims during camera loss, zero metric rows during LiDAR or pose
loss, zero late-result reintroduction and explicit recovery no later than
0.25 safter the fault interval. - The E34 profile, TTL, association gates and bounds remain frozen. E35 may vary only the declared source/channel transformation.
- Persistent reconstruction, planner input, commands, navigation and safety authority remain unavailable.
Consequences
- A passed E35 closes A8 only as a source-scoped diagnostic/shadow degradation contract.
- Safe degradation is represented as explicit loss of confidence and capability, not as guessed class, extrapolated free space or a green aggregate status.
- A failed scenario remains immutable evidence. Threshold relaxation or a new transformation definition requires a new profile and result rather than rewriting E35.
- E36 remains the first transfer/generalization gate and requires an eligible second mounted real source with the frozen E32–E35 profile.
Outcome
Immutable result:
e35-degradation-recovery-82bdbd5c5bfde6d932737f077153c3a8472c993c343fcbe8a207c39bfa2a6288.
All six variants replayed all 4,489 frames, producing 26,934 terminal outcomes
and 360 injection records. Maximum recovery was 0.102 s against the
predeclared 0.25 s gate. Hidden success, false-free rows, camera-less semantic
claims, LiDAR/pose-less metric rows, timing-mismatch agree, late-result
reintroduction and upstream mutations were all zero. E35 is accepted and A8
is closed; A9/E36 is next.