Files
NODEDC_MISSION_CORE/src/k1link/fleet/equipment_actions.py
T

47 lines
2.3 KiB
Python
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
"""Firmware-qualified commands, separate from desired configuration/profile writes."""
from k1link.device_plugins.arnavi_b2.usb_protocol import decode_configuration
from .independent_equipment import Document, EquipmentError, EquipmentStore
KINDS = {"request-position", "pulse-output", "set-output", "restart"}
def plan(equipment: EquipmentStore, row: Document, command: Document) -> Document:
if row["model_id"] != "arnavi-b2" or row["observed"]["firmware"] != "0.01":
raise EquipmentError("Команды для этой версии устройства не проверены.")
kind = command.get("kind")
if kind not in KINDS:
raise EquipmentError("Эта команда не поддерживается.")
config = decode_configuration(
(equipment.root / "evidence" / row["evidence_id"] / "configuration.bin").read_bytes()
)
allowed = {"kind"}
if kind in ("pulse-output", "set-output"):
allowed |= {"pin", "seconds" if kind == "pulse-output" else "enabled"}
pin = command.get("pin")
if type(pin) is not int or pin not in (4, 5, 6):
raise EquipmentError("Выберите выход PIN4–PIN6.")
seconds = command.get("seconds")
if kind == "pulse-output" and (type(seconds) is not int or not 1 <= seconds <= 5):
raise EquipmentError("Длительность импульса — от 1 до 5 секунд.")
if kind == "set-output" and type(command.get("enabled")) is not bool:
raise EquipmentError("Укажите включение или выключение выхода.")
if config.integer(16 + pin, 1) != 1:
raise EquipmentError("У выбранного выхода не подтверждён ручной режим управления.")
if set(command) != allowed:
raise EquipmentError("Некорректные параметры команды.")
private = (
{}
if kind in ("request-position", "restart")
else {"encoding": "text", "password": config.text(5)}
)
return {
**command,
**private,
"imei": row["identity_key"],
"model": 231,
"firmware": "0.01",
"secondary": {"host": config.text(3), "port": config.integer(4, 2)},
}