feat(bms): add read-only diagnostics and guarded operating switch commands

This commit is contained in:
DCCONSTRUCTIONS
2026-11-04 17:14:54 +03:00
parent ab8e977f11
commit 42213001ba
19 changed files with 919 additions and 40 deletions
@@ -21,7 +21,12 @@ func TestBMSProjectionRequiresVersionAndStableIdentity(t *testing.T) {
if bmsProjection(item, model) {
t.Fatal("wrong physical identity accepted")
}
if len(model.Actions) != 0 || model.PrepareUnit != "" || model.Vendor != "" {
t.Fatal("BMS must remain automatic and read-only")
if len(model.Actions) != 3 || model.PrepareUnit != "" || model.Vendor != "" {
t.Fatal("BMS must remain automatic with only three admitted operations")
}
for _, action := range []string{"bms.read", "bms.control.verify", "bms.control.set"} {
if !model.Actions[action] {
t.Fatalf("missing admitted action %s", action)
}
}
}
@@ -39,7 +39,7 @@ var sensorModels = []sensorModel{
Actions: actions("prepare", "details", "rename", "verify", "start", "replay", "stop", "option", "offer", "close-peer")},
{ID: "xgrids.k1", Name: "XGRIDS K1", Prefix: "k1", Kind: "k1",
ActionTimeouts: map[string]time.Duration{"management": 35 * time.Second},
Actions: actions("details", "rename", "verify", "start", "stop", "option", "offer", "close-peer", "management")},
Actions: actions("details", "rename", "verify", "start", "stop", "option", "offer", "close-peer", "management")},
{ID: "insta360.x4", Name: "Insta360 X4", Prefix: "instax4", Kind: "insta360.x4", Plugin: "missioncore.insta360", Version: "0.1.3",
// 2e1a:0002 is shared with other Insta360 models. Require the exact
// OS product descriptor as well; SDK identity is verified after prepare.
@@ -56,8 +56,8 @@ var sensorModels = []sensorModel{
Vendor: "04d8", Product: "0053", USBName: "USB CANFD DEBUG", Socket: "/run/mission-core-usb-can/driver.sock",
PrepareUnit: "mission-core-node-usb-can-prepare.service", Report: "/var/lib/mission-core-node-profiles/usb-can/preparation.json",
ProtocolIdentity: true, Actions: actions("prepare", "details", "rename", "verify", "can.status", "can.configure", "can.start", "can.stop", "can.clear", "can.transmit.preview", "can.transmit.apply", "can.transmit.stop")},
{ID: "jk.bms", Name: "JK BMS", Prefix: "jkbms", Kind: "jk.bms", Plugin: "missioncore.jk-bms", Version: "0.1.0",
Socket: "/run/mission-core-jk-bms/driver.sock", Actions: actions()},
{ID: "jk.bms", Name: "JK BMS", Prefix: "jkbms", Kind: "jk.bms", Plugin: "missioncore.jk-bms", Version: "0.2.0",
Socket: "/run/mission-core-jk-bms/driver.sock", Actions: actions("bms.read", "bms.control.verify", "bms.control.set")},
}
func modelForDevice(id string) *sensorModel {
@@ -2,13 +2,13 @@ package node
import (
"encoding/json"
"strings"
"strings"
"time"
)
// Configuration browsing is a bounded snapshot, not a durable backup or write receipt.
func sensorSnapshot(action string) bool {
return strings.HasPrefix(action, "can.") || action == "vesc.qml.open" || action == "vesc.qml.frame" || action == "vesc.qml.close" || action == "vesc.samples.start" || action == "vesc.samples.status" || action == "vesc.samples.fetch" || action == "vesc.samples.stop" || action == "vesc.samples.read" || action == "vesc.qml.begin" || action == "vesc.qml.chunk" || action == "vesc.qml.render" || action == "vesc.packages.catalog" || action == "vesc.packages.inspect" || action == "vesc.packages.download" || action == "vesc.packages.begin" || action == "vesc.packages.chunk" || action == "vesc.packages.load" || action == "vesc.packages.forget" || action == "vesc.packages.status" || action == "vesc.packages.prepare" || action == "vesc.packages.remove_prepare" || action == "vesc.packages.restore" || action == "vesc.packages.reconcile" || action == "vesc.packages.refresh" || action == "vesc.bms.configuration.read" || action == "vesc.bms.configuration.preview" || action == "vesc.bms.configuration.reconcile" || action == "vesc.bms.configuration.restore" || action == "vesc.code.read" || action == "vesc.code.begin" || action == "vesc.code.chunk" || action == "vesc.code.prepare" || action == "vesc.code.erase_prepare" || action == "vesc.code.reconcile" || action == "vesc.code.control_prepare" || action == "vesc.code.stats" || action == "vesc.code.restore" || action == "vesc.firmware.backup" || action == "vesc.firmware.target" || action == "vesc.bms.read" || action == "vesc.bms.prepare" || action == "vesc.firmware.catalog" || action == "vesc.tools.read" || action == "vesc.terminal.read" || action == "vesc.firmware.status" || action == "vesc.configuration.read" || action == "vesc.configuration.preview" || action == "vesc.diagnostics.read"
return strings.HasPrefix(action, "bms.") || strings.HasPrefix(action, "can.") || action == "vesc.qml.open" || action == "vesc.qml.frame" || action == "vesc.qml.close" || action == "vesc.samples.start" || action == "vesc.samples.status" || action == "vesc.samples.fetch" || action == "vesc.samples.stop" || action == "vesc.samples.read" || action == "vesc.qml.begin" || action == "vesc.qml.chunk" || action == "vesc.qml.render" || action == "vesc.packages.catalog" || action == "vesc.packages.inspect" || action == "vesc.packages.download" || action == "vesc.packages.begin" || action == "vesc.packages.chunk" || action == "vesc.packages.load" || action == "vesc.packages.forget" || action == "vesc.packages.status" || action == "vesc.packages.prepare" || action == "vesc.packages.remove_prepare" || action == "vesc.packages.restore" || action == "vesc.packages.reconcile" || action == "vesc.packages.refresh" || action == "vesc.bms.configuration.read" || action == "vesc.bms.configuration.preview" || action == "vesc.bms.configuration.reconcile" || action == "vesc.bms.configuration.restore" || action == "vesc.code.read" || action == "vesc.code.begin" || action == "vesc.code.chunk" || action == "vesc.code.prepare" || action == "vesc.code.erase_prepare" || action == "vesc.code.reconcile" || action == "vesc.code.control_prepare" || action == "vesc.code.stats" || action == "vesc.code.restore" || action == "vesc.firmware.backup" || action == "vesc.firmware.target" || action == "vesc.bms.read" || action == "vesc.bms.prepare" || action == "vesc.firmware.catalog" || action == "vesc.tools.read" || action == "vesc.terminal.read" || action == "vesc.firmware.status" || action == "vesc.configuration.read" || action == "vesc.configuration.preview" || action == "vesc.diagnostics.read"
}
func expiredSensorSnapshot(value SensorOperation) SensorOperation {
@@ -22,9 +22,11 @@ func expiredSensorSnapshot(value SensorOperation) SensorOperation {
// unacknowledged remote result to admit a new request. Tombstones retain
// operation identity, so retrying an old ID cannot execute hardware work again.
func (s *Sensors) writeOperation(value *SensorOperation) error {
// CAN requests/results are bounded RAM. On restart every USB generation is
// replaced; queued old-session commands cannot execute or replay TX.
if strings.HasPrefix(value.Command.Action, "can.") && value.Result == nil { return nil }
// CAN requests/results are bounded RAM. On restart every USB generation is
// replaced; queued old-session commands cannot execute or replay TX.
if (strings.HasPrefix(value.Command.Action, "can.") || strings.HasPrefix(value.Command.Action, "bms.")) && value.Result == nil {
return nil
}
if !sensorSnapshot(value.Command.Action) || value.Result == nil {
return s.write(value.Command.ID+".json", value)
@@ -61,7 +63,9 @@ func (s *Sensors) writeOperation(value *SensorOperation) error {
*entry = expiredSensorSnapshot(*entry)
}
}
if strings.HasPrefix(value.Command.Action, "can.") { return nil }
persisted := expiredSensorSnapshot(*value)
if strings.HasPrefix(value.Command.Action, "can.") || strings.HasPrefix(value.Command.Action, "bms.") {
return nil
}
persisted := expiredSensorSnapshot(*value)
return s.write(value.Command.ID+".json", &persisted)
}
@@ -59,3 +59,23 @@ func TestConfigurationBackupsRemainDurable(t *testing.T) {
t.Fatal("backup receipt was discarded")
}
}
func TestBMSCommandsAndReadbacksNeverPersistOrReplayFromDisk(t *testing.T) {
s := &Sensors{root: t.TempDir(), operations: map[string]*SensorOperation{}}
for _, action := range []string{"bms.read", "bms.control.verify", "bms.control.set"} {
op := &SensorOperation{Command: SensorCommand{ID: action, Action: action}, State: "running", Updated: time.Now().Unix()}
s.operations[action] = op
if err := s.writeOperation(op); err != nil {
t.Fatal(err)
}
op.State = "complete"
op.Result = map[string]any{"settings": map[string]any{"value": 42}}
if err := s.writeOperation(op); err != nil {
t.Fatal(err)
}
}
files, err := os.ReadDir(s.root)
if err != nil || len(files) != 0 {
t.Fatal("BMS commands or measurements escaped RAM", err)
}
}
+1 -1
View File
@@ -12,7 +12,7 @@ import sys
ROOT = Path(__file__).resolve().parents[1]
BINARY_VERSION = "0.8.53"
VERSION = "0.8.53-112"
VERSION = "0.8.53-113"
sys.path.insert(0, str(ROOT.parents[1] / "scripts/packaging"))
from debian import package
+18 -14
View File
@@ -1,8 +1,11 @@
# JK BMS: доступные данные и потенциал управления
Срез источников: 2026-11-04. Это исследование возможностей, не приёмка новых
команд на аккумуляторе. Настройки BMS не менялись. После просьбы владельца
проверки оборудования и пробное выключение не запускались.
Обновлено 2026-11-04 после поставки Node 0.8.53-113. Дополнительные поля
и чтение настроек внедрены. Команды заряда, разряда и балансировки доступны
с подтверждением; на реальной BMS проверена запись прежних значений и полное
обратное чтение без изменения настроек. Фактическое отключение MOS и выключение
борта не выполнялись. Точный протокол, аудит исходников и ограничения:
[контракт управления](47_JK_BMS_OPERATING_CONTROL.md).
## Наш профиль и уже реализованное чтение
@@ -19,15 +22,15 @@
[контракт интеграции](JK_BMS_BLUETOOTH.md). Это поля нашего декодера, а не
обещание всех возможностей семейства JK.
## Что можно добавить для наблюдения
## Дополнительные данные, внедрённые в Node113
| Возможность | Практическая ценность и граница подтверждения |
|---|---|
| Минимальная, максимальная и средняя ячейка, номер наиболее отклоняющейся | Можно вычислять из уже получаемых напряжений, без новых команд BMS. |
| Сопротивления измерительных/балансировочных цепей и маска проблем проводов | В описании JK02_32S есть соответствующие поля. Их ещё нужно проверить на нашей 11.47; нельзя называть их лабораторным внутренним сопротивлением ячеек. |
| Понятные причины защиты | Расшифровка битов вместо HEX; нужны подтверждённая раскладка этой версии и сохранение неизвестных битов. |
| Текущие пороги напряжения, тока, температуры, настройки балансировки и сна | Отдельный кадр настроек. Наши запросы уже включают 0x96, но текущий декодер использует телеметрию, а кадр настроек пока не публикует. |
| Серийный номер BMS, показатель здоровья от BMS | В upstream-парсере предусмотрены поля. Это номер контроллера и оценка его прошивки, не артикул CATL и не измеренная остаточная ёмкость. |
| Минимальная, максимальная и средняя ячейка, номер наиболее отклоняющейся | Вычисляются из полученных напряжений, без новых команд BMS. |
| Сопротивления измерительных/балансировочных цепей и маска проблем проводов | Прочитаны на 11.47; это измерительная цепь, не лабораторное внутреннее сопротивление ячеек. |
| Понятные причины защиты | Расшифровка JK02, исходный HEX и неизвестные биты сохранены. |
| Текущие пороги напряжения, тока, температуры, настройки балансировки и сна | Кадр настроек 0x01 публикуется после запроса 0x96. Числовые параметры доступны только для чтения. |
| Серийный номер BMS, показатель здоровья от BMS | Поля добавлены в allowlist декодера. Это номер контроллера и оценка его прошивки, не артикул CATL и не измеренная остаточная ёмкость. |
Основания: [описание BLE-протокола](https://github.com/syssi/esphome-jk-bms/blob/main/docs/protocol-design-ble.md),
[парсер aiobmsble](https://github.com/patman15/aiobmsble/blob/main/aiobmsble/bms/jikong_bms.py),
@@ -39,7 +42,7 @@
фактическую ёмкость из нынешнего потока получить нельзя. Время до разряда
можно только оценивать по нагрузке; при нулевом токе полезной оценки нет.
## Управление: существует в проектах, ещё не принято для нашей прошивки
## Управление и границы проверки
ESPHome предоставляет переключение зарядного и разрядного MOS, балансировки,
сна, ряд порогов и калибровок. В примере также есть команды перезапуска,
@@ -55,10 +58,11 @@ ESPHome предоставляет переключение зарядного
изменения до выяснения состояния.
[Границы поддержки batmon](https://github.com/fl4p/batmon-ha/blob/master/doc/JK-Settings.md).
Для Mission Core следующий полезный шаг — расширение чтения в существующем
плагине. Если позже вводить управление, необходимы свежий сеанс, отдельное
подтверждение, чтение результата и запрет повторного исполнения старой команды
после переподключения. Порог токовой защиты не является регулятором мощности
Mission Core реализует только три рабочих переключателя: заряд, разряд и
балансировка. Свежий сеанс, отдельное подтверждение, fingerprint настроек,
обратное чтение и запрет повторного исполнения старой команды обязательны.
Проверка на нашей плате ограничена записью уже установленных значений; фактическое
изменение MOS не проверялось. Порог токовой защиты не является регулятором мощности
зарядника или двигателя. Отключение разрядного MOS может обесточить сам борт;
последующее дистанционное включение тогда требует независимого питания.
Выключение ОС через кнопку борта — другая операция, оно не отключает MOS BMS.
+90
View File
@@ -0,0 +1,90 @@
# JK BMS operating controls
Scope: JK_BD6A17S6P, hardware 11.XA, firmware 11.47, JK02_32S layout.
Other models keep discovery/read qualification independent from write authority.
## Protocol and limits
The existing owner uses BlueZ service FFE0, characteristic FFE1,
`write-without-response` and notifications. The notification subscription makes
only the normal temporary CCCD change. Reads use registers 0x97 (identity) and
0x96 (settings/status). The driver never pairs, resets an adapter, runs a second
BLE client, or disconnects a peer owned by another client.
Only three fixed 20-byte operating frames can be encoded: header AA5590EB,
register 0x1D charge / 0x1E discharge / 0x1F balance, length 4, a little-endian
uint32 equal to zero or one, zero padding, sum-of-first-19 checksum. No arbitrary
address/value, protection-setting, SOC calibration, reset, password, emergency
or firmware API is exposed. In settings response 0x01, the corresponding uint32
values are at offsets 118, 122 and 126. Enabled means permission to operate;
BMS protections can still keep a MOS or balancer inactive.
An explicit operator confirmation sends a session-bound, expiring request.
Before sending, the driver rereads settings and checks the confirmation's
fingerprint, BLE generation, qualified identity, cell count, fresh telemetry
and protection/wiring flags. Password reminder bit 19 is informational; unknown
bits and every other active flag block changes. The query settles for at least
one second before a write. After the write, a fresh 0x96 query checks the complete
settings payload: exactly the selected bool may change; all other bytes must
remain equal. There is no blind write retry or automatic opposite command.
A lost link, timeout or unexpected readback after sending is **unknown**, not
success. Subsequent writes are blocked for that runtime instance; reads remain
available. Resolve the actual state before restarting/requalifying. Restarts
change session identity and cannot revive queued old requests. Reusing an
operation ID cannot repeat the physical write. Node and Core receipts and
telemetry stay bounded in RAM; persisted tombstones cannot replay commands.
Restoring an operating state is another explicitly confirmed command after a
fresh read, not an automatic rollback. Turning discharge off can remove board
power and require local recovery. No automated test is allowed to cut board
power. Numeric protection settings and calibration are never modified by this
feature, including the verification operation.
`bms.control.verify` is an engineering-only, low-current (<=0.2 A) check which
writes each switch's **existing** value and compares the whole readback. It
checks command framing and unchanged settings, but cannot prove that changing
a MOS/balancer state actuates hardware. Synthetic tests cover actual requested
transitions and failure paths without a radio.
## Sources reviewed
The adapter is implemented locally, not by executing/vendor-installing a whole
upstream application. Reviewed immutable source snapshots:
- [batmon-ha c58a670](https://github.com/fl4p/batmon-ha/tree/c58a670abc722483b503ab6a89f835b60e971230), MIT: common settings, switch frames, one-second query settling.
- [ESPHome JK BMS 0bd4063](https://github.com/syssi/esphome-jk-bms/tree/0bd4063e459ae6ed95e767288b32daefc6049dbf), Apache-2.0: offsets, switch registers, JK02 status-bit meanings.
- [aiobmsble 705ea16](https://github.com/patman15/aiobmsble/tree/705ea1609243bc4bcda3584e556a92077d58b5e6), Apache-2.0: read-only transport/parser comparison.
This is a bounded source review, not an audit of every upstream dependency.
The batmon identity path logs a Bluetooth password field at INFO; its standalone
example also toggles a switch. Neither behaviour is copied or executed. Identity
is an explicit allowlist; raw frames, password fields and arbitrary write APIs
are not returned or logged. Source hashes, qualification results and live-test
limitations are retained in local `outputs/bms-integration-20261104`.
## Readout semantics
Telemetry offset 178 is the BMS's full/effective capacity estimate; settings
frame offset 130 is configured nominal capacity. Neither measures actual cell
health independently. SOH is the reported BMS estimate. Wiring resistance is
measurement-lead resistance, not cell internal resistance. Unknown warning bits
remain visible. A disconnected battery can retain its last valid SOC for the
current UTC day (maximum 24 hours, bounded RAM) while freshness is shown stale.
At expiry or before the first reading, an independently editable, non-emissive
fallback surface is used. No measurement is written into the scene profile.
## Prepared-board acceptance, 2026-11-04
Node 0.8.53-113 installed through owner release e59c35fe4f83b5c98cea3b0a.
Package validation and installer completed; Node, BMS, VESC, USB-CAN, K1 and
RealSense remained active, X4 0.1.3-30 unchanged. This is prepared Ubuntu 24.04
amd64 acceptance, not a clean-host qualification.
At 14:01:26–14:01:43 UTC, the real paired Core→Node→BLE path completed bms.read
and bms.control.verify. Charge/discharge/balance were already true and each
was written as true. Whole settings fingerprint was identical before/after.
No MOS-off, calibration, threshold, password, firmware or board shutdown was
requested. Actual hardware switching remains untested. Readout confirmed 13
channels, 118 Ah configured capacity, reported SOH, cell extrema and wiring
resistances. Local evidence: outputs/bms-integration-20261104/live-check.json.
+108
View File
@@ -0,0 +1,108 @@
"""Node113 over qualified Node112; replace reviewed BMS/UI only."""
import argparse
import hashlib
import io
import json
import runpy
import sys
import tarfile
from pathlib import Path
REPO = Path(__file__).resolve().parents[3]
NODE = REPO / "apps/node-agent"
VERSION = "0.8.53-113"
BASE_SHA = "a67521b9647c3f8e02849cde5adb3bcb8d5f50370e61559da8c6aef3692b6e29"
sys.path.insert(0, str(REPO / "scripts/packaging"))
from debian import package # noqa: E402
def build(binary, output):
if output.exists():
raise FileExistsError("Published releases are immutable")
raw = (NODE / "build/power-112/mission-core-node_0.8.53-112_amd64.deb").read_bytes()
if hashlib.sha256(raw).hexdigest() != BASE_SHA:
raise ValueError("Qualified baseline changed")
stream = io.BytesIO(raw)
assert stream.read(8) == b"!<arch>\n"
archives = {}
while header := stream.read(60):
size = int(header[48:58])
archives[header[:16].decode().strip().rstrip("/")] = stream.read(size)
if size % 2:
stream.read(1)
def members(name):
with tarfile.open(fileobj=io.BytesIO(archives[name]), mode="r:gz") as archive:
return [(m.name, archive.extractfile(m).read(), m.mode) for m in archive if m.isfile()]
controls, files = members("control.tar.gz"), members("data.tar.gz")
old = {n: d for n, d, _ in files}
compiled = binary.read_bytes()
assert compiled[:6] == b"\x7fELF\x02\x01" and compiled[18:20] == b"\x3e\x00"
sources = {
str(p.relative_to(REPO)): hashlib.sha256(p.read_bytes()).hexdigest()
for root in (
REPO / "plugins/jk-bms",
NODE / "internal",
NODE / "cmd",
NODE / "web/dist",
REPO / "packages/sensor-ui/src",
)
for p in sorted(root.rglob("*"))
if p.is_file() and "__pycache__" not in p.parts
}
provenance = dict(
schema="missioncore.node.packaging-revision/v1",
version=VERSION,
qualified_base_sha256=BASE_SHA,
qualified_base_provenance=json.loads(
old["usr/share/doc/mission-core-node/provenance.json"]
),
scope="Reviewed JK diagnostics and expiring three-switch controls; no numeric writes",
binary_sha256=hashlib.sha256(compiled).hexdigest(),
source_files=sources,
)
changes = {
"usr/lib/mission-core-node/node-agent": compiled,
"usr/share/doc/mission-core-node/provenance.json": (
json.dumps(provenance, indent=2) + "\n"
).encode(),
}
added = []
for name, data, mode in runpy.run_path(str(Path(__file__).with_name("payload.py")))[
"payload"
]():
if name in old:
changes[name] = data
else:
added.append((name, data, mode))
replaced = []
for name, data, mode in controls:
if name == "control":
assert b"Version: 0.8.53-112\n" in data
data = data.replace(b"Version: 0.8.53-112\n", f"Version: {VERSION}\n".encode())
replaced.append((name, data, mode))
files = [(name, changes.get(name, data), mode) for name, data, mode in files] + added
output.parent.mkdir(parents=True, exist_ok=True)
output.write_bytes(package(replaced, files))
report = dict(
version=VERSION,
base_sha256=BASE_SHA,
sha256=hashlib.sha256(output.read_bytes()).hexdigest(),
bytes=output.stat().st_size,
changed_controls=["control"],
changed_payloads=[name for name, data in changes.items() if old.get(name) != data],
added_payloads=[n for n, _, _ in added],
retained_payload_count=sum(data == old.get(name) for name, data, _ in files),
)
output.with_suffix(".json").write_text(json.dumps(report, indent=2) + "\n")
print(json.dumps(report))
if __name__ == "__main__":
parser = argparse.ArgumentParser()
parser.add_argument("--binary", type=Path, required=True)
parser.add_argument("--output", type=Path, required=True)
args = parser.parse_args()
build(args.binary, args.output)
+2 -2
View File
@@ -1,5 +1,5 @@
"""Read-only JK BLE equipment plugin. No settings or power-control operations."""
"""JK BLE equipment plugin. Read diagnostics and three reviewed operating switches."""
MODEL = "jk.bms"
VERSION = "0.1.0"
VERSION = "0.2.0"
PLUGIN = "missioncore.jk-bms"
+26 -1
View File
@@ -10,6 +10,7 @@ import time
import dbus
from dbus.mainloop.glib import DBusGMainLoop
from .operations import Operations
from .protocol import (
CHARACTERISTIC,
SERVICE,
@@ -20,6 +21,7 @@ from .protocol import (
supported,
telemetry,
)
from .settings import decode_settings, switch_command
DEVICE = "org.bluez.Device1"
ADAPTER = "org.bluez.Adapter1"
@@ -30,6 +32,8 @@ class Observer:
def __init__(self, service):
DBusGMainLoop(set_as_default=True)
self.service = service
self.operations = Operations(service, self)
service.operations = self.operations
self.bus = dbus.SystemBus()
self.scanning = set()
self.seen = {}
@@ -91,6 +95,10 @@ class Observer:
self.finish("unsupported_firmware", delay=300)
return
a["verified"] = True
elif frame[4] == 1 and a.get("verified"):
settings = decode_settings(frame)
self.service.settings(a["address"], settings)
self.operations.received(a["address"], frame, settings)
elif frame[4] == 2 and a.get("verified"):
self.service.sample(a["address"], telemetry(frame))
a["last_sample"] = time.monotonic()
@@ -104,6 +112,7 @@ class Observer:
self.scanning.discard(path)
def finish(self, reason, delay=None):
self.operations.finish("Bluetooth-сеанс завершён; команда не повторяется.")
a, self.active = self.active, None
if not a:
return
@@ -133,6 +142,13 @@ class Observer:
)
a["last_query"] = time.monotonic()
def write_switch(self, name, enabled):
self.interface(self.active["characteristic"], GATT).WriteValue(
dbus.Array(switch_command(name, enabled), signature="y"),
dbus.Dictionary({"type": dbus.String("command")}, signature="sv"),
timeout=3,
)
def tick(self):
if self.closed:
return False
@@ -174,11 +190,20 @@ class Observer:
if a.get("verified") and not a.get("requested"):
self.write_read(0x96)
a["requested"] = True
self.operations.tick()
if (
a.get("verified")
and a.get("last_sample")
and now - a.get("settings_query", a["started"]) > 60
and not self.operations.job
):
self.write_read(0x96)
a["settings_query"] = now
if a.get("last_query") and now - a.get("last_sample", a["last_query"]) > 12:
self.finish("read_timeout")
elif not a.get("last_sample") and now - a["started"] > 45:
self.finish("connect_timeout")
elif now - a["started"] > 120:
elif now - a["started"] > 120 and not self.operations.job:
# Fairness: refresh discovery so a second BMS can be admitted.
self.finish("reconnecting", delay=5)
return True
+250
View File
@@ -0,0 +1,250 @@
"""Single-flight, expiring BMS operations on the observer's existing BLE link."""
import copy
import re
import threading
import time
from datetime import datetime
from .protocol import supported
from .settings import SWITCHES, unchanged_except
class Operations:
def __init__(self, service, observer):
self.service, self.observer = service, observer
self.lock = threading.RLock()
self.job = None
self.receipts = {}
self.blocked = set()
def execute(self, request):
with self.lock, self.service.lock:
identifier = request.get("operation_id", "")
if (
not re.fullmatch(r"op_[0-9a-f]{32}", identifier)
or request.get("idempotency_key") != identifier
):
raise ValueError("Неверный идентификатор операции.")
if identifier in self.receipts:
previous, result = self.receipts[identifier]
if previous != request:
raise ValueError("Идентификатор уже использован.")
return copy.deepcopy(result)
self.receipts = {
key: value
for key, value in self.receipts.items()
if datetime.fromisoformat(
value[0]["deadline_at"].replace("Z", "+00:00")
).timestamp()
> time.time()
}
if self.job or len(self.receipts) >= 128:
raise ValueError("Дождитесь завершения операции BMS.")
action = request.get("action_id")
if action not in ("bms.read", "bms.control.verify", "bms.control.set"):
raise ValueError("Команда BMS не поддерживается.")
deadline = datetime.fromisoformat(
request["deadline_at"].replace("Z", "+00:00")
).timestamp()
if not 0 < deadline - time.time() <= 25:
raise ValueError("Срок команды истёк. Обновите показания.")
session = request["session"]
if not isinstance(session, dict):
raise ValueError("Неверный сеанс BMS.")
address, d = next(
(
(a, d)
for a, d in self.service.devices.items()
if d["id"] == session["device_id"]
),
(None, None),
)
if (
d is None
or d["session"] != session["session_id"]
or not supported(d["identity"] or {})
):
raise ValueError("Сеанс или профиль BMS изменился.")
parameters = request.get("parameters", {})
if not isinstance(parameters, dict):
raise ValueError("Неверные параметры команды.")
if action == "bms.control.set":
if (
set(parameters) != {"switch", "enabled", "fingerprint", "link_generation"}
or parameters["switch"] not in SWITCHES
or type(parameters["enabled"]) is not bool
):
raise ValueError("Допустимы только заряд, разряд и балансировка.")
if parameters["link_generation"] != d["link_generation"]:
raise ValueError("Bluetooth переподключился. Обновите показания.")
elif parameters:
raise ValueError("У команды нет дополнительных параметров.")
if action != "bms.read" and d["identity"].get("hardware") != "11.XA":
raise ValueError("Управление этой аппаратной версией не проверено.")
if action != "bms.read" and address in self.blocked:
raise ValueError(
"Результат предыдущей записи не подтверждён. Управление заблокировано."
)
job = dict(
request=copy.deepcopy(request),
address=address,
session=d["session"],
generation=d["link_generation"],
expires=time.monotonic() + min(20, deadline - time.time()),
phase="queued",
sent=False,
event=threading.Event(),
)
self.job = job
job["event"].wait(22)
with self.lock:
if not job["event"].is_set():
self.finish("Связь не подтвердила результат операции.")
return copy.deepcopy(job["result"])
def finish(self, error=None, result=None):
with self.lock:
job, self.job = self.job, None
if not job:
return
if error and job["sent"]:
self.blocked.add(job["address"])
value = {"state": ("unknown" if job["sent"] else "error") if error else "complete"}
if error:
value["error"] = error
else:
value["result"] = result
job["result"] = value
self.receipts[job["request"]["operation_id"]] = (job["request"], value)
job["event"].set()
def tick(self):
with self.lock, self.service.lock:
job = self.job
if not job:
return
a = self.observer.active
d = self.service.devices[job["address"]]
if (
time.monotonic() >= job["expires"]
or not a
or a["address"] != job["address"]
or not a.get("verified")
or d["session"] != job["session"]
or d["link_generation"] != job["generation"]
or not d["sample"]
or d["state"] != "streaming"
or self.service.clock() - d["sampled"] >= 5
):
self.finish("Нет свежего подтверждённого соединения с BMS.")
return
if job["phase"] == "queued":
job["phase"] = "before"
job["query_at"] = time.monotonic()
self.observer.write_read(0x96)
elif job["phase"] == "write_ready" and time.monotonic() - job["query_at"] >= 1:
if (
d["sample"].get("protection_mask", 1) & ~(1 << 19)
or d["sample"].get("wire_warning_cells")
or not d["settings"]
or d["settings"]["fingerprint"] != job["fingerprint"]
or (
job["request"]["action_id"] == "bms.control.verify"
and abs(d["sample"]["current_a"]) > 0.2
)
):
self.finish("Состояние BMS изменилось до записи. Подтвердите заново.")
return
job.update(sent=True, phase="settle", read_after=time.monotonic() + 0.3)
# No retry: a GATT exception can happen after the device accepted the frame.
self.observer.write_switch(job["switch"], job["enabled"])
elif job["phase"] == "settle" and time.monotonic() >= job["read_after"]:
job["phase"] = "after"
job["query_at"] = time.monotonic()
self.observer.write_read(0x96)
def received(self, address, frame, settings):
with self.lock, self.service.lock:
job = self.job
if not job or job["address"] != address or job["phase"] not in ("before", "after"):
return
if time.monotonic() >= job["expires"]:
self.finish("Срок подтверждения BMS истёк.")
return
d = self.service.devices[address]
action, parameters = job["request"]["action_id"], job["request"].get("parameters", {})
if (
not d["sample"]
or self.service.clock() - d["sampled"] >= 5
or d["session"] != job["session"]
or d["link_generation"] != job["generation"]
):
self.finish("Сеанс или свежие показания BMS потеряны.")
return
if settings["values"]["cell_count"] != d["sample"]["cell_count"]:
self.finish("Настройки не совпадают с числом измеряемых ячеек.")
return
if job["phase"] == "before":
if action == "bms.read":
self.finish(result={"settings": settings, "link_generation": job["generation"]})
return
if parameters and parameters["fingerprint"] != settings["fingerprint"]:
self.finish("Настройки изменились. Обновите сведения и подтвердите снова.")
return
if d["sample"].get("protection_mask", 1) & ~(1 << 19) or d["sample"].get(
"wire_warning_cells"
):
self.finish("BMS сообщает о защите или проводах. Управление недоступно.")
return
job["before"] = frame
if action == "bms.control.verify":
if abs(d["sample"]["current_a"]) > 0.2:
self.finish("Для проверки требуется ток не более 0,2 А.")
return
job["remaining"] = list(SWITCHES)
else:
name, enabled = parameters["switch"], parameters["enabled"]
if settings["switches"][name] == enabled:
self.finish(
result={
"unchanged": True,
"switch": name,
"enabled": enabled,
"settings": settings,
}
)
return
job["remaining"] = [name]
else:
name, enabled = job["switch"], job["enabled"]
if not unchanged_except(job["before"], frame, name, enabled):
self.finish(
"Ответ BMS не совпал с ожидаемым; дальнейшее управление заблокировано."
)
return
job["before"] = frame
if not job["remaining"]:
self.finish(
result={
"verified_readback": True,
"verification": "same-value-only"
if action == "bms.control.verify"
else "requested-state",
"settings": settings,
"link_generation": job["generation"],
}
)
return
name = job["remaining"].pop(0)
enabled = (
settings["switches"][name]
if action == "bms.control.verify"
else parameters["enabled"]
)
job.update(
switch=name,
enabled=enabled,
phase="write_ready",
fingerprint=settings["fingerprint"],
)
+15 -3
View File
@@ -1,6 +1,7 @@
"""JK02_32S profile qualified against BD6A17S6P / 11.47.
Only 0x97 (identity) and 0x96 (telemetry subscription) can be constructed.
Only read requests are constructed here. Operating switches have a separate
strict encoder in settings.py; protection/calibration writes are absent.
Never expose the raw identity frame: it contains unrelated credential fields.
"""
@@ -63,7 +64,7 @@ class Frames:
if len(self.buffer) < 300:
break
frame = bytes(self.buffer[:300])
if sum(frame[:-1]) & 255 != frame[-1]:
if frame[4] not in (1, 2, 3) or sum(frame[:-1]) & 255 != frame[-1]:
del self.buffer[0]
self.rejected += 1
continue
@@ -85,6 +86,7 @@ def identity(frame):
"firmware": field(30, 38),
"name": field(46, 62),
"manufactured_raw": field(78, 84),
"serial_number": field(86, 97),
}
@@ -121,12 +123,22 @@ def telemetry(frame):
"power_w": round(voltage * current, 3),
"power_source": "voltage_times_current",
"remaining_ah": u(174) / 1000,
"configured_capacity_ah": u(178) / 1000,
"configured_capacity_ah": None,
"effective_capacity_ah": u(178) / 1000,
"reported_health_percent": u(190, 1) if u(190, 1) <= 100 else None,
"cycle_count": u(182),
"cycle_capacity_ah": u(186) / 1000,
"cell_count": count,
"cell_voltages_v": cells,
"cell_delta_v": u(76, 2) / 1000,
"cell_min_v": min(cells),
"cell_max_v": max(cells),
"cell_average_v": round(sum(cells) / count, 4),
"cell_min_index": cells.index(min(cells)) + 1,
"cell_max_index": cells.index(max(cells)) + 1,
"wire_resistances_ohm": [u(80 + i * 2, 2) / 1000 for i in range(count)],
"wire_warning_cells": [i + 1 for i in range(count) if u(146) & (1 << i)],
"protection_mask": u(166),
"charge_mos_on": bool(u(198, 1)),
"discharge_mos_on": bool(u(199, 1)),
"runtime_s": u(194),
+27 -4
View File
@@ -1,4 +1,4 @@
"""Local read-only inventory endpoint; no public port or arbitrary GATT API."""
"""Private inventory and allowlisted operations; no public port or raw GATT API."""
import json
import os
@@ -37,6 +37,9 @@ class Handler(BaseHTTPRequestHandler):
def log_message(self, *args):
pass
def do_POST(self):
self.do_GET()
def do_GET(self):
_, uid, _ = struct.unpack(
"3i", self.connection.getsockopt(socket.SOL_SOCKET, socket.SO_PEERCRED, 12)
@@ -45,12 +48,32 @@ class Handler(BaseHTTPRequestHandler):
if uid != self.server.node_uid or not re.fullmatch(r"[a-zA-Z0-9_.:-]{1,128}", node):
self.send_error(403)
return
if self.path != "/inventory":
self.send_error(404)
try:
if self.headers.get("Transfer-Encoding"):
raise ValueError("Недопустимый формат запроса.")
if self.command == "GET" and self.path == "/inventory":
result = self.server.service.inventory(node)
elif self.command == "POST" and self.path == "/operation":
size = int(self.headers.get("Content-Length", "0"))
if not 0 < size <= 8192 or self.headers.get("Content-Type") != "application/json":
raise ValueError("Недопустимый размер запроса.")
raw = self.rfile.read(size)
if len(raw) != size:
raise ValueError("Неполный запрос.")
request = json.loads(raw)
if not isinstance(request, dict):
raise ValueError("Недопустимый запрос.")
result = self.server.service.operations.execute(request)
else:
self.send_error(404)
return
except (ValueError, KeyError, TypeError, OSError):
self.send_error(400, "Invalid or unavailable BMS operation")
return
payload = json.dumps(self.server.service.inventory(node), allow_nan=False).encode()
payload = json.dumps(result, allow_nan=False).encode()
self.send_response(200)
self.send_header("Content-Type", "application/json")
self.send_header("Cache-Control", "no-store")
self.send_header("Content-Length", str(len(payload)))
self.end_headers()
self.wfile.write(payload)
+27
View File
@@ -24,6 +24,7 @@ class Service:
self.instance = "jkbms_" + uuid.uuid4().hex
self.devices = {}
self.revision = 0
self.operations = None
self.day = datetime.now(UTC).date()
for path in sorted(self.root.glob("jkbms_*.json"))[:8]:
try:
@@ -52,6 +53,9 @@ class Service:
adapter=None,
rssi_dbm=None,
link_generation=0,
settings=None,
settings_at=None,
settings_received=0,
)
d = self.devices[address]
d.update(adapter=adapter, rssi_dbm=rssi)
@@ -78,9 +82,22 @@ class Service:
os.replace(temporary, destination)
self.revision += 1
def settings(self, address, settings):
with self.lock:
self.devices[address].update(
settings=copy.deepcopy(settings), settings_at=utc(), settings_received=self.clock()
)
self.revision += 1
def sample(self, address, sample):
with self.lock:
self.expire()
settings = self.devices[address].get("settings")
if settings:
sample = {
**sample,
"configured_capacity_ah": settings["values"]["nominal_capacity_ah"],
}
self.devices[address].update(
sample=copy.deepcopy(sample),
sample_at=utc(),
@@ -98,6 +115,8 @@ class Service:
for d in self.devices.values():
if today != self.day or self.clock() - d["sampled"] >= 300:
d.update(sample=None, sample_at=None)
if today != self.day or self.clock() - d["settings_received"] >= 300:
d.update(settings=None, settings_at=None)
self.day = today
def inventory(self, node):
@@ -118,6 +137,8 @@ class Service:
"adapter",
"rssi_dbm",
"link_generation",
"settings",
"settings_at",
)
}
status.update(
@@ -125,6 +146,12 @@ class Service:
address=address,
fresh=online,
compatible=supported(info),
control_available=online
and supported(info)
and info.get("hardware") == "11.XA"
and bool(d["settings"])
and address not in (self.operations.blocked if self.operations else set()),
control_locked=bool(self.operations and address in self.operations.blocked),
sample_ttl_s=300,
)
items.append(
+85
View File
@@ -0,0 +1,85 @@
"""Read-only JK02_32S settings; no numeric setting encoder exists here.
Offsets cross-checked with pinned ESPHome/batmon sources in the capability doc.
The entire frame remains private RAM for command readback comparison.
"""
import hashlib
from .protocol import HEADER
# name, offset, divisor, signed. Only the common 11.x fields are admitted.
FIELDS = (
("sleep_voltage_v", 6, 1000, False),
("cell_uvp_v", 10, 1000, False),
("cell_uvpr_v", 14, 1000, False),
("cell_ovp_v", 18, 1000, False),
("cell_ovpr_v", 22, 1000, False),
("balance_trigger_v", 26, 1000, False),
("soc100_voltage_v", 30, 1000, False),
("soc0_voltage_v", 34, 1000, False),
("requested_charge_voltage_v", 38, 1000, False),
("requested_float_voltage_v", 42, 1000, False),
("poweroff_voltage_v", 46, 1000, False),
("max_charge_current_a", 50, 1000, False),
("charge_ocp_delay_s", 54, 1, False),
("charge_ocp_recovery_s", 58, 1, False),
("max_discharge_current_a", 62, 1000, False),
("discharge_ocp_delay_s", 66, 1, False),
("discharge_ocp_recovery_s", 70, 1, False),
("short_circuit_recovery_s", 74, 1, False),
("max_balance_current_a", 78, 1000, False),
("charge_overtemp_c", 82, 10, True),
("charge_overtemp_recovery_c", 86, 10, True),
("discharge_overtemp_c", 90, 10, True),
("discharge_overtemp_recovery_c", 94, 10, True),
("charge_undertemp_c", 98, 10, True),
("charge_undertemp_recovery_c", 102, 10, True),
("mos_overtemp_c", 106, 10, True),
("mos_overtemp_recovery_c", 110, 10, True),
("nominal_capacity_ah", 130, 1000, False),
("short_circuit_delay_us", 134, 1, False),
("balance_start_voltage_v", 138, 1000, False),
)
SWITCHES = {"charging": (0x1D, 118), "discharging": (0x1E, 122), "balancing": (0x1F, 126)}
def decode_settings(frame):
if len(frame) != 300 or frame[:5] != HEADER + b"\x01" or sum(frame[:-1]) & 255 != frame[-1]:
raise ValueError("Invalid settings frame")
values = {
name: int.from_bytes(frame[offset : offset + 4], "little", signed=signed) / scale
for name, offset, scale, signed in FIELDS
}
values["cell_count"] = int.from_bytes(frame[114:118], "little")
switches = {
key: int.from_bytes(frame[offset : offset + 4], "little")
for key, (_, offset) in SWITCHES.items()
}
if not 1 <= values["cell_count"] <= 32 or any(v not in (0, 1) for v in switches.values()):
raise ValueError("Unsupported settings layout")
if not (
0 < values["cell_uvp_v"] < values["cell_ovp_v"] < 5
and 0 < values["nominal_capacity_ah"] < 100000
):
raise ValueError("Inconsistent settings layout")
return {
"values": values,
"switches": {key: bool(v) for key, v in switches.items()},
"fingerprint": hashlib.sha256(frame[6:299]).hexdigest(),
}
def switch_command(name, enabled):
if name not in SWITCHES or type(enabled) is not bool:
raise ValueError("Only three boolean operating switches are supported")
data = bytes.fromhex("aa5590eb") + bytes([SWITCHES[name][0], 4, int(enabled)]) + bytes(12)
return data + bytes([sum(data) & 255])
def unchanged_except(before, after, name, enabled):
"""Compare every settings byte, excluding counter/CRC and the requested bit."""
expected = bytearray(before[6:299])
offset = SWITCHES[name][1] - 6
expected[offset : offset + 4] = int(enabled).to_bytes(4, "little")
return bytes(expected) == after[6:299]
+1 -1
View File
@@ -93,7 +93,7 @@ def test_identity_allowlist_and_candidate_are_not_compatibility():
data[:5] = HEADER + b"\x03"
data[6:18] = b"JK_BD6A17S6P"
data[30:35] = b"11.47"
data[90:96] = b"SECRET"
data[97:103] = b"SECRET"
info = identity(data)
assert supported(info) and "SECRET" not in json.dumps(info)
assert not supported({**info, "firmware": "14.00"})
+222
View File
@@ -0,0 +1,222 @@
"""Synthetic transport: no radio, real battery, or OS services are accessed."""
# ruff: noqa: E402
import concurrent.futures
import time
import uuid
from datetime import UTC, datetime, timedelta
from types import SimpleNamespace
import pytest
from jkbms_test_runtime.operations import Operations
from jkbms_test_runtime.settings import SWITCHES, decode_settings, switch_command, unchanged_except
from test_bms import HEADER, Service, frame, telemetry
def settings_frame(**switches):
data = bytearray(300)
data[:5] = HEADER + b"\x01"
for offset, value in [(10, 2800), (18, 4250), (98, -50), (114, 13), (130, 120000)]:
data[offset : offset + 4] = value.to_bytes(4, "little", signed=value < 0)
for key, (_, offset) in SWITCHES.items():
data[offset : offset + 4] = int(switches.get(key, True)).to_bytes(4, "little")
data[-1] = sum(data[:-1]) & 255
return bytes(data)
def test_encoder_cannot_address_numeric_settings_and_decoder_rejects_corruption():
raw = settings_frame()
value = decode_settings(raw)
assert value["values"]["nominal_capacity_ah"] == 120
assert value["values"]["charge_undertemp_c"] == -5
for name, (register, _) in SWITCHES.items():
for enabled in (True, False):
encoded = switch_command(name, enabled)
assert len(encoded) == 20 and encoded[:6] == bytes.fromhex("aa5590eb") + bytes(
[register, 4]
)
assert int.from_bytes(encoded[6:10], "little") == int(enabled)
assert encoded[-1] == sum(encoded[:-1]) & 255
for bad in (1, 0, None, "true", [], {}):
with pytest.raises(ValueError):
switch_command(name, bad)
for name in ("soc", "voltage", "capacity", "password", "firmware", "reset", 0x6E):
with pytest.raises(ValueError):
switch_command(name, True)
for bad in (raw[:-1], raw[:70] + bytes([raw[70] ^ 1]) + raw[71:], frame()):
with pytest.raises(ValueError):
decode_settings(bad)
assert unchanged_except(raw, settings_frame(charging=False), "charging", False)
assert not unchanged_except(
raw, settings_frame(charging=False, balancing=False), "charging", False
)
assert telemetry(frame())["effective_capacity_ah"] == 118
assert telemetry(frame())["configured_capacity_ah"] is None
@pytest.fixture
def rig(tmp_path):
service = Service(tmp_path)
address = "AA:BB:CC:DD:EE:01"
service.observe(address, "hci7", -50)
service.identify(address, {"model": "JK_BD6A17S6P", "firmware": "11.47", "hardware": "11.XA"})
sample = {**telemetry(frame()), "current_a": 0, "protection_mask": 1 << 19}
service.sample(address, sample)
service.settings(address, decode_settings(settings_frame()))
reads, writes = [], []
observer = SimpleNamespace(
active={"address": address, "verified": True},
write_read=reads.append,
write_switch=lambda *args: writes.append(args),
)
operations = Operations(service, observer)
service.operations = operations
pool = concurrent.futures.ThreadPoolExecutor(max_workers=1)
def request(action, parameters=None):
identifier = "op_" + uuid.uuid4().hex
return dict(
operation_id=identifier,
idempotency_key=identifier,
action_id=action,
deadline_at=(datetime.now(UTC) + timedelta(seconds=20)).isoformat(),
session={
"device_id": service.devices[address]["id"],
"session_id": service.devices[address]["session"],
},
parameters=parameters or {},
)
def start(req):
future = pool.submit(operations.execute, req)
until = time.monotonic() + 1
while not operations.job and not future.done() and time.monotonic() < until:
time.sleep(0.001)
operations.tick()
return future
def receive(raw):
value = decode_settings(raw)
service.settings(address, value)
operations.received(address, raw, value)
def write_ready():
operations.job["query_at"] -= 2
operations.tick()
operations.job["read_after"] -= 1
operations.tick()
yield SimpleNamespace(
service=service,
address=address,
op=operations,
reads=reads,
writes=writes,
request=request,
start=start,
receive=receive,
write_ready=write_ready,
)
operations.finish("test teardown")
pool.shutdown()
def test_read_and_noop_set_never_mutate(rig):
for action, params in [
("bms.read", {}),
(
"bms.control.set",
dict(
switch="charging",
enabled=True,
fingerprint=decode_settings(settings_frame())["fingerprint"],
link_generation=0,
),
),
]:
req = rig.request(action, params)
f = rig.start(req)
rig.receive(settings_frame())
assert f.result(1)["state"] == "complete"
assert rig.op.execute(req) == f.result() and not rig.writes
def test_verify_writes_only_current_values_once_and_checks_entire_readback(rig):
req = rig.request("bms.control.verify")
f = rig.start(req)
rig.receive(settings_frame())
rig.op.tick()
assert not rig.writes # query must settle first
for name in SWITCHES:
rig.write_ready()
assert rig.writes[-1] == (name, True)
rig.receive(settings_frame())
assert f.result(1)["result"]["verification"] == "same-value-only"
rig.op.execute(req)
assert len(rig.writes) == 3
def test_mutation_readback_and_idempotency(rig):
params = dict(
switch="balancing",
enabled=False,
fingerprint=decode_settings(settings_frame())["fingerprint"],
link_generation=0,
)
req = rig.request("bms.control.set", params)
f = rig.start(req)
rig.receive(settings_frame())
rig.write_ready()
rig.receive(settings_frame(balancing=False))
assert f.result(1)["state"] == "complete" and rig.writes == [("balancing", False)]
assert rig.op.execute(req) == f.result()
with pytest.raises(ValueError):
rig.op.execute({**req, "parameters": {**params, "enabled": True}})
def test_uncertain_disconnect_and_side_effect_block_future_writes(rig):
f = rig.start(rig.request("bms.control.verify"))
rig.receive(settings_frame())
rig.write_ready()
rig.receive(settings_frame(balancing=False))
assert f.result(1)["state"] == "unknown"
with pytest.raises(ValueError):
rig.op.execute(rig.request("bms.control.verify"))
f = rig.start(rig.request("bms.read"))
rig.receive(settings_frame())
assert f.result(1)["state"] == "complete" # reading remains possible
def test_old_session_deadline_generation_fingerprint_and_fault_rejected(rig):
base = rig.request("bms.read")
for req in (
{**base, "deadline_at": "2000-01-01T00:00:00Z"},
{**base, "session": {**base["session"], "session_id": "old"}},
{**base, "action_id": "bms.reset"},
):
with pytest.raises(ValueError):
rig.op.execute(req)
req = rig.request(
"bms.control.set",
dict(switch="charging", enabled=False, fingerprint="old", link_generation=0),
)
f = rig.start(req)
rig.receive(settings_frame())
assert f.result(1)["state"] == "error" and not rig.writes
f = rig.start(rig.request("bms.control.verify"))
rig.receive(settings_frame())
rig.service.devices[rig.address]["sample"]["protection_mask"] = 2
rig.op.job["query_at"] -= 2
rig.op.tick()
assert f.result(1)["state"] == "error" and not rig.writes
def test_transport_loss_after_write_is_unknown_without_retry(rig):
f = rig.start(rig.request("bms.control.verify"))
rig.receive(settings_frame())
rig.write_ready()
rig.op.finish("connection lost")
assert f.result(1)["state"] == "unknown" and len(rig.writes) == 1
for _ in range(3):
rig.op.tick()
assert len(rig.writes) == 1
+5 -2
View File
@@ -15,7 +15,7 @@ from functools import wraps
def ephemeral(action):
return action.startswith(("vesc.samples.", "vesc.qml.", "can."))
return action.startswith(("vesc.samples.", "vesc.qml.", "can.", "bms."))
def synchronized(method):
@@ -83,7 +83,10 @@ class SensorTransient:
).encode()
if len(raw) <= 16384:
self.bms[key] = (previous[0] if same else self.clock(), raw)
status.update(sample=None, sample_at=None, fresh=False, rssi_dbm=None)
status.update(
sample=None, sample_at=None, fresh=False, rssi_dbm=None,
settings=None, settings_at=None, control_available=False,
)
item.update(bms_status=status, online=False)
items.append(item)
result["sensor_state"] = {**row["sensor_state"], "items": items}
+1
View File
@@ -10,6 +10,7 @@ from missioncore_plugin_sdk.v0alpha2.session import DeviceSessionSnapshot
from .trust import PairingError
ACTIONS = {
"bms.read", "bms.control.verify", "bms.control.set",
"can.status", "can.configure", "can.start", "can.stop", "can.clear", "can.transmit.preview", "can.transmit.apply", "can.transmit.stop",
"prepare",
"details",